• Home
  • Store
    • Facial devices
    • Body devices
    • Lasers
      • Hair removal lasers
      • Vascular lesions removal lasers
      • Tattoo removal lasers
    • RF Fractional Microneedling
    • 3D HIFU
    • Cryolipolysis
    • EMS – muscle building
  • About us
  • Blog
  • Contact
Home / Lasers / Hair removal lasers / Medilase Pro – hair epilation with 4 wavelengths
Compare
Medilase Pro - hair epilation with 4 wavelengths
Medilase Pro - hair epilation with 4 wavelengths - Image 2
Medilase Pro - hair epilation with 4 wavelengths - Image 3
Brands

Medilase Pro – hair epilation with 4 wavelengths

Medilase Pro is everything You need to have when buying hair removal laser. 4 wavelengths, advanced TEC handpiece cooling, modern design and medical certificate provides quick, safe, ‘pain-free’ laser hair removal treatments, on all skin types. Combination of four wavelengths in one handpiece enables You to remove light, dark and red hair. 

Handpieces quantity: 1
Treatment area: Face and body
Housing-type: Tower
Touch screen: 12'

Advantages

  • painless treatment
  • enormous laser power
  • advanced TEC cooling system
  • long lifespan

Effects

  • permanent light and dark hair removal
  • smooth skin without shaving
  • red hair removal
Tel.: +44 737 943 67 60

Do You want to get a better price? Contact us

SKU: medilase-pro Categories: Hair removal lasers, Lasers, Products Tags: Body devices, Hair removal Brand: Medilase
  • Description
  • Additional information

Effective hair removal with 4 wavelengths

Medilase Pro is the latest diode laser with four wavelengths. Medilase Pro is a medical grade laser.

Using the VCSEL technology, the energy is distributed evenly over the entire skin area, which ensures greater efficiency and comfortable treatments.

Thanks to the use of different wavelengths, we have a much wider treatment spectrum. Treatments performed with Medilase Pro are very comfortable, fast and painless. The modern cooling system offers the possibility of the right temperature selection for different photo types and skin areas.

even 300 £

estimated profit per one treatment

7 treatments a month

provide quick return on investment (when buying on 60 installments)

Laser epilation technology

Laser beam targets the hair follicles. The light is absorbed and transformed into heat. As a result, the cells responsible for hair growth are damaged and hair stops growing. The diode laser has been shown to be the most effective in hair removal.

The hair melanin absorbs the beam and as a result the hair is significantly damaged. Cell division is stopped, hair stops to grow and falls out. Medilase Pro laser epilation provides permanent hair removal of all body areas

Laser handpiece

Medilase Pro hair removal device has optimally sized laser handpiece, that uses 4 wavelenghts in the most optimal way. In addition, thanks to special cooling system, it is possible to adjust right temperature, according to different treatment area and skin phototype. Laser handpiece may reach the temperature of -16 °C to perform painless hair removal treatment. Handpiece has a spot size of 20 mm x 12 mm.

Control treatment parameters using handpiece display ! You are able to control given energy and temperature. Ergonomic size and silicone button provide comfortable handpiece usage.

What distinguishes the Medilase Pro laser from other lasers ?

10,4 inch LCD-display
360 degrees rotation
Safe mounting of the handpiece





LCD display on the handpiece

Technology of 4 wavelengths

The technology of laser hair removal is based on selective photothermolysis. The laser light reaches the hair follicles. The light is absorbed and transformed into heat. As a result, the cells responsible for hair growth are damaged and hair stops growing. The diode laser has been shown to be the most effective in hair removal.

• 755 nm is a wavelength used to remove light, thin  and shallowly embedded hair

• 808 nm is a wavelength used to remove dark, thick and deeply embedded hair

• 940 nm is a wavelength used to remove dark and light, shallowly embedded hair

• 1064 nm is a wavelength used to remove shallowly embedded, dark hair

How does Medilase Pro remove unwanted hair ?

The laser light reaches the hair follicles. The light is absorbed and transformed into heat. As a result, the cells responsible for hair growth are damaged and hair stops growing. The diode laser has been shown to be the most effective in hair removal.

The melanin contained in hair absorbs the beam and as a result the hair is significantly damaged. Cell division is stopped, hair stops growing and falls out. Medilase Pro laser epilation enables permanent hair removal from all areas of the body

Medilase Pro laser handle 

High-quality, german origin emitters guarantee a very long lifespan of the handpiece. The weight of the 2000 W handle is 600 g. It increases comfort of treatment performance.

Medilase Pro -quick return on investment

The light handpiece makes the operator’s work easier. The cooling module maintains the water temperature in the range of 20 to 25 degrees Celsius. Thanks to the advanced TEC cooling technology, the device can be used continuously for 48 hours.

 The treatment handle screen displays the appropriate cooling temperature, making the operation safe.

Technical components of Medilase Pro

1. Main fuse

2. Handpiece socket

3. Vent

4. Interlock and food pedal

5. Water inlet

6. Water outlet

Technical aspects of Medilase Pro

1. Integrated water tank

Integrated water tank: 5 liter high-quality tank. Fast water circulation and constant temperature, which ensures excellent fluid quality and long lifespan.

2. German production water pump

The circulating water flow rate is 5 l / min

3. Power

Low power consumption and high power stability. Constant regulation of frequency and output current.

4. Cooling system

A cooling system that maintains a constant water temperature of approx. 20-25 degrees Celsius

How does Medilase Pro remove hair ?

Before treatment

Laser hair removal treatment can be performed on many parts of the body and face. Laser epilation allows you to get rid of hair for a very long time.r.

During the treatment

During the epilation treatment, the laser beam of a certain length is absorbed by melanin in the hair follicle. The beam goes down the hair follicle and damages it. This damages the parts of the hair that are responsible for its growth. The hair stops growing back.

After the treatment

After the laser epilation treatment, the anagen hair is damaged. Damaged hair stops growing back. The skin in the treatment area is smooth, the hair does not grow back.

A modern Medilase Pro interface

The modern interface of the Medilase Pro diode laser enables even more precise adjustment of parameters. The operator of the device can select the pulse length and its frequency.

The Medilase Pro device operates in two modes – normal and fast. Both are suitable for all skin types. In addition, the quick mode also has a “memory” function, which allows you to remember settings.

Treatment head with VCSEL technology

Using VCSEL technology, the energy is evenly distributed over the entire skin area, ensuring greater efficiency and comfortable treatments.

Long service life of the treatment handpiece

High-quality transmitters guarantee a very long service life of the laser handpiece

Technical data:
Wavelengths755, 808, 940, 1064 nm
Handpiece power2000 W
Laser Power5000 W
Frequency1-20 Hz
Spot size20×10 mm
Cooling temperaturedown to -16 ° C
Pulse duration10-100 ms
The set includes:
  • 2 years of warranty
  • post warranty service
  • professional training
  • personalized certificate
  • learning and marketing material
  • consent form with contraindications
  • user manual
  • device
  • laser handpiece
  • protective box
Buying and financing:
  • cash
  • leasing
  • subsidy
  • installments

Additional information

Touch screen

12'

Handpieces quantity

1

Treatment area

Face and body

Housing-type

Tower

Device power

4500 W

Laser handpiece power

3000 W

Handpiece lifespan

30 mln pulses

Spot size

12,5 x 15,4 mm, 13.5 x 28,5 mm, 13.5x 38.5 mm, 8,22 mm (diameter)

Energy

5-80 J /cm²

Frequency

1-10 Hz

Cooling system

water+air

Cooling

down to -16 °C

Beam type

755+808+1064 nm

Voltage

220-230V 50/60HZ

Pulse duration

5-100 ms

Related products

  • Estelle System-  5 slimming technologies

    Estelle System- 5 slimming technologies

    Compare
  • Sculptor Compact - muscles building

    Sculptor Compact – muscles building

    Compare
  • Power EMS - body contouring and shaping device

    Power EMS – body contouring and shaping device

    Compare
  • 3D HIFU Prime

    3D HIFU Prime

    Compare

Professional solutions for beauty industry.

Menu

  • My account
  • Cart
  • Store

Categories

  • Devices comparison
  • My account
  • Order
  • Cart
  • Store
+ 44 737 943 67 60